Internet Library 5.42 Release note
- Nov 1, 2010
- Author: Sierra Wireless
- Version: 1
- NEW FEATURES
- SOFTWARE RELEASE DESCRIPTION
2.1 Software Identification
2.2 Compatibility - KNOWN RESTRICTIONS
- INTERFACE MODIFICATIONS
- CORRECTIONS & IMPROVEMENTS
AT+WIPCREATE? To ease sockets control awareness by host processor, AT+WIPCREATE? command now delivers the list of current opened sockets.
2. Software Release Description
|
Software Identification |
WIPLib 5.42 / WIPSoft 5.42 |
|
Applications built with this Open AT® OS version |
|
Open AT® OS 6.34 or higher |
|
Firmware> 7.3 mandatory for WIPLib and Firmware>7.4a for WIPSoft |
|
ID |
Description (What / When) |
Impacted Domain |
Impacted Sub Domain |
|
59087 |
When trying to set the data representation type at UART2 using WIPSoft command AT+WIPOPT=4,1,2,40,x, after the FTP connection is made the expected OK response is not received. |
WIPSoft |
OTHER |
|
55607 |
'+++' sequence is not sent as data when option AT_WIP_NET_OPT_ESC_SEQ_NOT_SENT is set to 0 using AT+WIPCFG command. |
WIPSoft |
OTHER |
|
60917 |
While trying to execute WIPSoft commands using function adl_atCmdSendExt() from a command handler of customized command, subscribed in an embedded application, then sometimes response to WIPSoft commands is not received. |
WIPLib |
OTHER |
|
60192 |
When a TCP session is opened and then closed using wip_close() function at a very fast rate, it is not possible to create any more socket after few iterations. |
WIPLib |
OTHER |
|
59494 |
GPRS bearer is not started if wip_bearerStart() is called in the +CGREG unsolicited handler. However, this can be achieved by starting the bearer in +CREG callback instead. |
WIPLib |
OTHER |
|
58386 |
Embedded module may reset while transferring MMS with file greater than 6KB in "chunked data transfer encoding". |
WIPLib |
OTHER |
|
57509 |
For SNMP protocol,oID should be changed to u32 from u8 to prevent data corruption. |
WIPLib |
OTHER |
|
56385 |
Ethernet bearer cannot be started once the Ethernet cable is unplugged and plugged again. |
WIPLib |
OTHER |
|
56165 |
If the network is lost (+WIND: 8 is received) between bearer start and reception of bearer connect event, Internet library is no more responsive and no event exchange takes place. |
WIPLib |
OTHER |
|
56164 |
The Embedded module may reset when network connection is lost during GPRS bearer stop operation. |
WIPLib |
OTHER |
|
55094 |
Ethernet bearer cannot be reopened after restarting the IP Stack. |
WIPLib |
OTHER |
|
55029 |
When an FTP server is established on UART PPP bearer, reset is observed while closing the stack without first closing the bearer. |
WIPLib |
OTHER |
|
55021 |
It is not possible to start the Ethernet bearer with DHCP enabled. Also with DHCP disabled, the Ethernet bearer does not get unsubscribed on removing the Ethernet cable. |
WIPLib |
OTHER |
|
54402 |
Sometimes the embedded module stops responding if the stack is closed before closing the open ethernet bearer. |
WIPLib |
OTHER |
|
54010 |
When using wip_list API, WIP_CEV_PEER_CLOSE event is not received after the last data is received. |
WIPLib |
OTHER |
|
52919 |
When file containing only DLE ETX character sequence is sent from TCP client to the server then data loss occurs and "SHUTDOWN" indication is received. |
WIPLib |
OTHER |
|
52499 |
Incorrect error codes are received when invalid peer IP address is given while trying to establish TCP Server Client connection. |
WIPLib |
OTHER |
This section lists the interfaces that have been modified from WIP 5.41.
|
Macro |
Comment |
|
AT+WIPCREATE |
Read command AT+WIPCREATE? To get the number of available sockets is available now. Only sockets created with +WIPCREATE command will be displayed in response of this command. |
|
ID |
Description (What / When) |
Impacted Domain |
Impacted Sub Domain |
Fixed in |
|
60150 |
On UART1, when trying to start or stop a GPRS bearer on any virtual port other than the virtual port on which GPRS bearer was opened, the OK response is received on the virtual port on which the GPRS bearer was opened instead on the same virtual port on which the command was issued. |
WIPSoft |
OTHER |
WIPSoft 5.42 |
|
60285 |
For MMS service, while using WIPSoft command AT+WIPOPT to attach the files, the embedded module gets reset if the total size increases more than 150Kbytes. |
WIPSoft |
OTHER |
WIPSoft 5.42 |
|
60271 |
Error is received while trying to upload/download a file with filename greater than 62 characters. However, the ‘filename‘parameter of ‘+WIPFILE’ command can take 128 characters. |
WIPLib |
OTHER |
WIPLib 5.42 |
|
43781 |
+CME ERROR:841 is received instead of +WIPPEERCLOSE when FTP session is closed by peer. |
WIPSoft |
OTHER |
WIPSoft 5.41 |
|
56102 |
No +WIPFILE indication received when using HTTP_POST method in AT+WIPFILE wipsoft command. |
WIPSoft |
OTHER |
WIPSoft 5.41 |
|
58000 |
+WIPPEERCLOSE indication is not received on closing the FTP channel manually using the command AT+WIPCLOSE=4,<idx> |
WIPSoft |
OTHER |
WIPSoft 5.41 |
|
59518 |
A new option has been added in AT+WIPBR to return detailed CME Error codes or a generic error (+CME ERROR: 812) in the case of GPRS set up is failure. |
WIPSoft |
OTHER |
WIPSoft 5.41 |
|
59551 |
Reset is observed if an attempt is made to establish a POP3 session over an index value greater than 9 using the AT+WIPCREATE command. |
WIPSoft |
OTHER |
WIPSoft 5.41 |
|
59569 |
WIP Plug-in component information is incorrect in WIPSoft. It is displayed as "foo Plug-in Package" with an incorrect version number. |
WIPSoft |
OTHER |
WIPSoft 5.41 |
|
56411 |
Compiling
a C++ application using WIPLib as Plug-in fails. Compilation errors are
received as some structure fields in a WIP header file are named as
Sierra Wireless defined data types. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
57579 |
After the local SIM is removed and the remote SIM is inserted while GPRS setup is in progress, the WIP bearer startup for the remote SIM fails and no notification or WIP plug-In event is sent for the same. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
58253 |
When SIM is removed, WIP_BEV_STOPPED event is not sent out when GPRS bearer is started using WIP. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
50608 |
In the case of GPRS set up is failure, WIP now returns specific error codes instead of a generalized event (WIP_BERR_GPRS_FAILED). |
WIPLib |
OTHER |
WIPLib 5.41 |
|
52249 |
The "+WIPPEERCLOSE" unsolicited indication is not received when the FTP channel is closed by the server due to time out. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
54171 |
When an error is generated on a TCP Channel, wip_getOpts() returns the correct error code in WIPLib but error code is not correctly displayed by WIPSoft. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
56368 |
WIP net init returns error -26 (WM_EINVAL) when called from task ID greater than 16. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
56731 |
Reconnecting to the Embedded module from Windows PC using PPP bearer fails even when WIP_BOPT_RESTART is set TRUE . Windows pops up Error:777 after attempted to reconnect. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
57970 |
TCP server socket could not be created using TCP server sample when WIP API wip_TCPServerCreateOpts() is being used in sample. |
WIPLib |
OTHER |
WIPLib 5.41 |
|
59853 |
Ethernet controller may not be stable when AHB (Advanced High-performance Bus) clock of the Embedded module is increased from 26Mhz to 52 MHz (using AT+WCPS). This is because the C-Ethernet plug-in SPI bus runs at 26MHz instead of 13MHz but the Microchip chip supports only upto 20MHz. |
WIP |
OTHER |
WIP 5.41 |
|
59121 |
When compared against iDE v1, stack size allocated in WipSoft application (compiled in RVDS and ADS) has increased when built using Developer Studio. |
WIP |
OTHER |
WIP 5.41 |
|
59166 |
When
compared against iDE v1, stack size allocated in WIP samples (compiled
in RVDS and ADS) has increased when built using Developer Studio. |
WIP |
OTHER |
WIP 5.41 |
|
57526 |
+CME ERROR: 847 is not received when the timer expires while trying to connect to GPRS bearer using WIPSoft. |
WIPSoft |
OTHER |
WIPSoft 5.40 |
|
57583 |
Peer port is displayed as 0 in +WIPDATA indication for UDP protocol. |
WIPSoft |
OTHER |
WIPSoft 5.40 |
|
56324 |
OK is not displayed when socket command subscription is successful. |
WIPSoft |
OTHER |
WIPSoft 5.40 |
|
57230 |
To prevent data corruption, MMS Transaction ID buffer has been increased from 10bytes to 11bytes. |
WIPLib |
OTHER |
WIPLib 5.40 |
|
57462 |
Repeated GPRS bearer start and stop along with stack open and close leads to module reset. |
WIPLib |
OTHER |
WIPLib 5.40 |
|
57504 |
User
receives +CME ERROR:847 and bearer gets disconnected when
AT+WIPBR=4,6,0 command is given at the time GPRS bearer is already
connected. |
WIPSoft |
OTHER |
WIPSoft 5.32 |
|
54436 |
On giving the command AT+WIPBR=2, 6, <opt num>, <value> where <opt num>=12/13/14/20 and value=alphabet/negative, user receives +CME ERROR: 800 instead of +CME ERROR: 801. |
WIPSoft |
OTHER |
WIPSoft 5.31 |
|
56360 |
WIP_BERR_NO_DEV error is received while opening Ethernet bearer with RVDS binary. It works fine with GCC compiled binary. User should not get this error irrespective of compiler being used i.e. GCC or RVDS. |
WIPSoft |
OTHER |
WIPSoft 5.31 |
|
56883 |
Creating and closing the HTTP sessions consecutively for sometimes causes Embedded module to reset. This is due to memory leak while opening and closing the HTTP Sessions. |
WIPSoft |
OTHER |
WIPSoft 5.31 |
|
53515 |
It is not possible to send data through UDP client socket in the continuous data mode, using WIPSoft application compiled on RVDS compiler. The Embedded module gets reset. Ideally, user should be able to exchange data over UDP socket using application compiled on any of the compilers: ADC/GCC/RVDS. |
WIPSoft |
OTHER |
WIPSoft 5.31 |
|
54615 |
When AT+WIPBR command is issued with "invalid value" for the option WIP_BOPT_LOGIN, OK response is received instead of +CME ERROR: 801. Note that this command is given after starting the stack (AT+WIPCFG=1) and opening the particular bearer (AT+WIPBR=1, 6). |
WIPSoft |
OTHER |
WIPSoft 5.31 |
|
54984 |
The user cannot retrieve the IP address values set through +WIPBR command, before or after starting the bearer. Ideally, the user should be able to retrieve the IP related values after starting the bearer. |
WIPSoft |
OTHER |
WIPSoft 5.31 |
|
55050 |
Using WIPSoft, the unsolicited indications +WIPDATA, +WIPACCEPT, +WIPFILE and +WIPREADY are not received on all the ports opened (USB, CMUX and UARTS). Ideally, these unsolicited indications should be received at all open ports. |
WIPSoft |
OTHER |
WIPSoft 5.31 |
|
53459 |
When wip_putfile () API is provided with invalid file path for FTP protocol, the event WIP_CEV_OPEN followed by WIP_CEV_WRITE event are received in the file data handler. The ideal behavior should have been receiving WIP_CEV_ERROR in file data handler. Note that, this behavior is observed only in passive mode of FTP and not in case of active mode FTP. |
WIPLib |
OTHER |
WIPLib 5.30 |
|
53549 |
The "WIP_BEV_STOPPED" event is not received when Ethernet bearer is stopped using wip_bearerStop () API. |
WIPLib |
OTHER |
WIPLib 5.30 |
|
54452 |
After activating PDP context with CID 1 with WIP bearer APIs, then the dialing ATD*99**2# with CID 2 freezes the dialing process. It is not possible to open another PDP context when bearer is started using WIP Plug-In. |
WIPLib |
OTHER |
WIPLib 5.30 |
|
54671 |
It is not possible to perform operations such as set or get options through an Embedded application, compiled with RVDS compiler. The error -998 is received from WIP Library. Ideally user should be able to perform the above operations on RVDS also, as already being able to successfully perform on other two compilers: GCC and ADS. |
WIPLib |
OTHER |
WIPLib 5.30 |
|
54982 |
User will not be able to create a socket after starting the Ethernet bearer, when DHCP is disabled. Ideally, user should be able to create a socket for both the cases: DHCP enabled or disabled. |
WIPLib |
OTHER |
WIPLib 5.30 |
|
55022 |
It is not possible to create a socket after starting the Ethernet bearer, "+CME ERROR: 803" is attained. Ideally the user should be able to create a socket after starting Ethernet bearer, irrespective whether DHCP is enabled or disabled. |
WIPLib |
OTHER |
WIPLib 5.30 |
|
56419 |
When mail is downloaded using POP3 protocol and WIPSoft application, data gets corrupted. Some characters are missing from the downloaded mail. |
WIPLib |
OTHER |
WIPLib 5.30 |
|
52954 |
Using WIPSoft, while creating an FTP/POP3/SMTP/HTTP/UDP session using “AT+WIPCREATE” command, if the peer port/local port number is not provided then “+CME ERROR 847” is returned. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
54438 |
For AT+WIPCREATE command (UDP) having port number with odd number of digits (within port range 1-65535) +CME ERROR: 800 are returned. Also, for port number out of bounds but having odd number of digits +CME ERROR: 800 is returned instead of +CME ERROR: 832. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
55648 |
When sending data using DTR toggling mode with WIPSoft, data loss occurs. Ideally there should not be any data loss. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
53546 |
OK is received before the CONNECT indication while downloading a file of small size from FTP server over UART PPP bearer. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
54789 |
Using WIPSoft, if the DTR signal is used to switch from DATA mode (ONLINE) to AT mode (OFFLINE), in some cases, the V24 request does not go in to OFFLINE. Even after manually trying +++ command the transition does not occur. Wireless CPU® has to be restarted to get out of this state. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
54049 |
Using WIPSoft, "+CME ERROR: 851" is returned when creating FTP/HTTP/SMTP/POP3 data channel with default value of optional parameter. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
54400 |
When Ethernet bearer is opened and closed multiple times using AT+WIPBR command then a reset is observed on Wireless CPU® most of the times. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
44584 |
Using WIPSoft, when an attempt is made to download a non-existing file from a FTP server, the FCM flow switches to data mode and CONNECT indication is received on the external application. |
WIPSoft |
OTHER |
WIPSoft 5.21 |
|
50057 |
Sometime for +WIPPING command, the number of PING response received is one less than the specified number of PING echo request specified(WIP_COPT_REPEAT). |
WIPLib |
OTHER |
WIPLib 5.20 |
|
51380 |
It is not possible to open a second PDP context using cid2 when bearer is started using Open AT® WIP Plug-In. |
WIPLib |
OTHER |
WIPLib 5.20 |
|
51761 |
FTP
data channel is closed by WIP when an error is raised by the socket. |
WIPLib |
OTHER |
WIPLib 5.20 |
|
52283 |
Response to a Ping request is not systematically sent to user application, whatever the timeout value. |
WIPLib |
OTHER |
WIPLib 5.20 |
|
52453 |
Sometime the “response_time” parameter is set zero with timeout parameter specified in the +WIPPING command. |
WIPLib |
OTHER |
WIPLib 5.20 |
|
54787 |
Unable to make multiple connections with IDS server when a Ping application is running in parallel |
WIPLib |
OTHER |
WIPLib 5.20 |
|
53931 |
When activating Ping channel to send several ping requests, if the channel is closed by application before completion of all ping requests, error -995 is reported. |
WIPLib |
OTHER |
WIPLib 5.20 |
|
46367 |
WIP_COPT_POP3_MAILSIZE option will return the value received by the 'LIST n' command and not the 'RETR n' command. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
47094 |
When an attempt is made to change the "Data representation TYPE" for FTP protocol using “AT+WIPOPT” command, the type is not set successfully for the FTP session. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
47660 |
Invalid value read from WIPSoft for option 7 (WIP_COPT_NODELAY) for TCP Channels. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
48994 |
With
current implementation, application can't manually set the Ethernet
link configuration and each try will set 10 Base T always. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
49013 |
Currently, customer can't read back value that was configured. After change, value of this option will be correctly returned. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
49268 |
Application
can set a 32bits value for NAT timeouts but can't read value if
>65535. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
49873 |
Result of ping function is a multiple of 500ms. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
49918 |
Wireless CPU® reset is observed while setting options with NULL MMS structure pointer. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50009 |
If you get an HTTPS page without initialized WIPSSL library, you get a reboot. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50410 |
WIP
does not fully release memory it was allocated. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50446 |
In a HTTP Client, an event WIP_CERR_CSTATE is generated at the final call of WIP_CEV_READ event. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50640 |
When the WIP sample applications are compiled with the Eclipse environment, the compilation fails. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50656 |
It is not possible to use specific socket parameters with high level protocol (such as FTP). |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50657 |
Customer application doesn't receive a DONE event for a file operation and so, it must wait sometimes after a PEER_CLOSE event on the data channel before issuing the next operation. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50679 |
A WIP_CEV_WRITE event is actually generated at the opening of an FTP file download channel. Filter in wrapper channel should allow application to receive only relevant events according the file operation. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
50806 |
If an UART is switched to DATA mode with wip_fcmCreate() then switched back to AT mode with "+++" escape sequence, no further subscription to that FCM port will succeed. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
51257 |
The HTTP method used is not traced properly. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
51261 |
Cannot send mms using Vodafone or Tim operator in Italy, as their service center reject anonymous message sending. |
WIPLib |
OTHER |
WIPLib 5.10 |
|
51437 |
unable to compile the TCP_CLIENT sample application in RTE mode using ECLPISE IDE |
WIPLib |
OTHER |
WIPLib 5.10 |
|
46887 |
Application can't set the Ethernet interface link configuration nor the promiscuous mode. |
WIPLib |
OTHER |
WIPLib 5.00 |
|
48103 |
When a finalizer is specified for the HTTP SESSION channel, it is called prematurely. |
WIPLib |
OTHER |
WIPLib 5.00 |
|
42734 |
No response is received if an attempt is made to exchange data for the second time for FTP/HTTP/SMTP/POP3 protocols. |
WIPLib |
OTHER |
WIPLib 4.00 |
|
45232 |
When An email is sent using SMTP protocol from an SMTP server, the body is not received correctly or the e-mail is not received at all. |
WIPLib |
OTHER |
WIPLib 4.00 |
|
47095 |
SMTP doesn't respect the RFC requirements for addresses encoding |
WIPLib |
OTHER |
WIPLib 4.00 |
|
47097 |
"AT+WIPPING" does not work for the first time when used with a DNS name |
WIPLib |
OTHER |
WIPLib 4.00 |
|
44666 |
It is not possible to create a PPP client on the Wireless CPU® which connects with the PPP server on the PC. |
WIPLib |
OTHER |
WIPLib 4.00 |
|
52786 |
Data loss is observed in the UART when a file is downloaded from the FTP server at lower baud rates especially at 9600 baud/s or below. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
51799 |
Data corruption occurs when a binary file is sent from a utility (UdpPktTest.exe) to the Wireless CPU®, (with WIPSoft application) in case of UDP protocol. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
53038 |
The “+WIPFILE” indication is not received after switching to AT mode on completion of get file request, through a HTTP session. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
52859 |
It is not possible to create an HTTP session without specifying the server address in WIPSoft. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
51445 |
Two CONNECT indications are received when file is uploaded using FTP protocol. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
43776 |
OK is not received when values are read using +WIPOPT command for FTP protocol. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
40606 |
Data can be lost if an attempt is made to write large amount of data to an UDP socket. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
51285 |
NET 10 level traces are not displayed in TMT to get the debug information when WIP Soft application is used. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
48612 |
In Wireless CPU®, during FTP download data loss is experienced. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
52861 |
Debug traces are not sent to USB port when activated using +WIPCFG command in WIPSoft. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
52224 |
Closing the PPP connection after creation of TCP socket leads to WCPU reset. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
51725 |
While uploading a file, if “+++” is issued to switch to AT mode, two “OK” responses are received in case of FTP protocol. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
50028 |
When the +WIPFILE command is used to retrieve data from server, the first chunk of data is not received. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
48164 |
Incorrect +CME ERROR codes are sent by WIPSOFT for PPP LINK failure and PPP Terminate requests. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
47657 |
Wrong error code is being displayed for the +WIPCREATE command. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
44320 |
Responses for file session are not sent to the port on which the file session is created for SMTP and POP3 protocols. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
43737 |
The “WIP_CERR_NOT_SUPPORTED” error code is received when an attempt is made to map an UDP socket to continuous mode of data transmission. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
52318 |
Unexpected "OK" indication is received before “+WIPPEERCLOSE” indication, in case of SMTP and POP3 protocol. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
51910 |
It is not possible to delete or retrieve a mail for the second time when the first attempt returns an error in case of POP3 protocol. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
47949 |
+WIPDATA, +WIPFILE and +WIPACCEPT unsolicited indications are not received with UART2, CMUX and USB ports. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
44436 |
Error codes returned by the “AT+WIPOPT” command for setting/retrieving different options for UDP, TCP server and TCP client sockets are not uniform. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
44364 |
No
response is attained if an attempt is made to create/start a
socket/session with less than/more than minimum/maximum number of
mandatory parameters for any protocol. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
44363 |
Negative option value for the FTP session returns “+CME ERROR: 800” error code instead of “+CME ERROR: 801”. |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
44362 |
Zero value for the “WIP_BOPT_GPRS_CID” option returns “OK” response though the valid value ranges from 1 to 4 |
WIPSoft |
OTHER |
WIPSoft 5.12 |
|
44370 |
Not able to use option WIP_WOPT_RCV_LOWAT provided by WIPSoft. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
51164 |
Customer application is unable to use HTTP GET request using WipSoft, especially using small web pages. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
51753 |
It is not possible to upload or download a file for the second time when the first trial returns an error in case of FTP protocol. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
51756 |
“OK” response returned for the invalid AT+WIPDATA command e.g.: AT+WIPDATA=2,1, or AT+WIPDATA=1,1, |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
51815 |
“CME ERROR:800” is returned when trying to upload a file without specifying the path i.e. AT+WIPFILE = 4,1,2,"ftptest.txt" |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
50888 |
UDP continuous transparent mode is not in compliant with GR64 behavior. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
47765 |
No response is received if an attempt is made to exchange data for the second time for FTP/HTTP/SMTP/POP3 protocols. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
41712 |
Data is lost while large chunk of data is sent/received for TCP and UDP protocol. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
48061 |
Unsolicited responses are sometimes not attained in the external application until an unless addition AT command is executed. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
44710 |
Add one new mode through +WIPCFG AT command to allow or not the “+++” escape sequence to be sent as data towards the remote IP device. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
45535 |
Recreation of TCP client socket is unsuccessful when the URL is used instead of IP address. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
37108 |
When
creating a socket with the wip_create() (wiplib) or AT+WIPCREATE
(wipsoft) just after the call of wipclose() (wiplib) or AT+WIPCLOSE
(from wipsoft) of that socket (same address and port) , that created
socket cannot function properly as expected because the socket closing
needs time and is not immediate. |
WIPSoft |
OTHER |
WIPSoft 5.11 |
|
47468 |
Data is lost while large chunk of data is sent/received for TCP and UDP protocol |
WIPSoft |
OTHER |
WIPSoft 5.01 |
Comment
Forum